Airguard Envirocare

PC2–AGCoalescer Panel Filters

Airguard Envirocare PC2-AG provide an OEM-equivalent coale cer panel filter for Altair Sy tem 2, Altair Neptune, Altair Vega and other compatible air intake y tem .

Coalescer Panel Filter
Request a quoteFact sheet
PC2-AG coalescer panel filter for gas turbine air intake

Brand

Airguard Envirocare

Flow Rate

Up to 9 m/s face velocity (1,771 FPM)

Division

Filtration

Efficiency

G3

Industry

Oil & Gas, Power Gen, Marine, Wind, HVAC

Temperature

n/a

Application

Offshore, Marine, Land-based

Height

Standard and non-standard, to holding frame

Technology

Coalescing and Mechanical Filtration (3-stage vane/coalescer/vane)

Width

Standard and non-standard, to holding frame

Product Type

Filter Panel

Depth

n/a

Product Style

Corrugated Coalescer Panel, Cleanable

OD

n/a

Media

Synthetic Media Core, between Stainless Steel Wire Mesh

ID

n/a

Construction

Stainless Steel 304L / 316L channel frame and mesh

Weight

2.5 KG or 5 lb

Classification

G3 (EN 779:2002); 80% gravimetric arrestance

Bespoke

Available

Request Pricing

Share part number/spec, dimensions, airflow and efficiency, and our team will respond within 24 hours.

We use the details you provide only to respond to your enquiry, as set out in our Privacy Policy. To ask about, correct or delete your data, see Your Data Rights.

Customer reviews4.7Based on 9 reviews
56
43
30
20
10
What customers mention
Low pressure drop, high dust holdingEffective and well madeConsistent between batchesExactly to spec, fast turnaroundSolid qualityWould order again

How ordering works

From purchase order to delivery on site. Every PC2–AG is built, checked and shipped by our own team.

01
Purchase Order
Confirm your quote and raise a PO. We acknowledge it and confirm lead time in writing.
02
Production
Your PC2–AG is made to order in our Wolverhampton factory, to your sizes.
03
Quality Assurance
Every filter is inspected under our ISO 9001:2015 quality management system.
04
Packing
Custom packaging and labelling, with test certification and documentation.
05
Shipping
Despatched worldwide with tracking, so purchasing and site teams stay informed.

Frequently Asked Questions

Common questions about PC2–AG.

The PC2-AG is designed to remove moisture droplets, salt mist and liquid aerosols from high-velocity air. It is used in turbine intake systems, offshore platforms, coastal power stations and marine propulsion applications.

Yes. The PC2-AG is an OEM-equivalent direct replacement for the Premaburg PC2 system and is also designed for compatible Altair System 2, Altair Neptune and Altair Vega air intake systems.

Yes. The PC2-AG uses cleanable synthetic coalescing media with stainless-steel support mesh. Its 304L or 316L stainless-steel construction allows the filter to be cleaned and reused for repeated service.

Yes. The PC2-AG is positioned for gas turbine ventilation and air intake applications, where a coalescer panel can be selected according to the installed system and environmental requirements.

The PC2-AG specification sheet publishes salt removal performance when used in an SRS Technology system, including 99.78% at 3 m/s, 99.95% at 6 m/s and 99.98% at 9 m/s for the listed PC2 configurations.

Yes. Airguard Envirocare specifically lists the PC2-AG for offshore wind turbine air intake applications, as well as gas turbine, engine, and HVAC systems.

Yes. Provide the existing OEM part number, filter dimensions, frame depth, airflow, and filtration specification. Airguard Envirocare can use this information to assess the appropriate PC2-AG or alternative coalescer panel replacement.

Both PC2-AG and PC1-AG are listed for gas turbine ventilation, diesel and gas engine intake, HVAC, and offshore wind applications. The correct filter should be selected by matching the existing specification, performance requirements, and physical dimensions rather than the product name alone.

PC2-AG should be selected according to the environmental conditions stated in its product specification, including factors such as dust, moisture, salt, humidity, temperature, and airborne contamination where applicable. The installed system and required filtration performance should be checked before selection.

Where PC2-AG is identified as Altair-compatible, Airguard Envirocare positions it as an OEM-equivalent or specification-matched replacement. Exact compatibility should be confirmed against the installed filter's part number, dimensions and required performance. The available product information identifies Altair System 2, Altair Neptune and Altair Vega compatibility and lists gas turbine, engine, HVAC and offshore wind applications.

Yes. Airguard Envirocare can provide available technical information for PC2-AG, including technical datasheets, technical drawings, and other relevant information on request.

The PC2-AG manufacturing origin is the United Kingdom.

Depending on the product, order requirements and delivery location, PC2-AG can be delivered in approximately 2 to 7 working weeks.

Use of an alternative filter should not be described as automatically voiding a gas turbine warranty. Warranty terms are set by the turbine OEM and the applicable contract, so customers should confirm the requirements with the OEM or operator before installation. Where this product is used as an OEM-equivalent replacement, its dimensions and performance specifications should be verified for the specific installation.

Yes. Airguard Envirocare offers a 12-month manufacturer's warranty for PC2-AG.

Can’t find it? Ask our team

Related Products

Explore other filter families that might suit your needs

Coalescer panel filter for gas turbine air intake

CP2–AG

Airguard Envirocare CP2-AG is an OEM-equivalent coalescer panel filter engineered for Altair System 2, Altair Neptune and Altair Vega air intake systems, offering a reliable replacement for equivalent OEM filters.

Marine
Power Generation
View Details
PC1-AG coalescer panel filter for gas turbine air intake

PC1–AG

Airguard Envirocare PC1-AG is an OEM-equivalent coalescer panel filter engineered for gas turbine ventilation, diesel and gas engine intake, HVAC, and offshore wind turbine air intake systems.

Power Generation
Oil & Gas
View Details
PBPI-AG panel filter for gas turbine and industrial air intake

PB1P-AG

Airguard Envirocare PB1P-AG is an OEM-equivalent coalescer panel filter engineered for Altair System 2, Altair Neptune and Altair Vega applications, helping protect air intake systems from moisture and liquid aerosols.

Power Generation
Oil & Gas
View Details
FSS-AG panel filter for gas turbine and industrial air intake

SMC-AG

Airguard Envirocare SMC-AG Coalescer Panel Filter is built for demanding air intake environments where high airflow, moisture and harsh conditions can put pressure on filtration systems. Its permanent stainless-steel construction has no media carryover risk and keeps pressure loss low at high air velocities. Available in standard and custom sizes, with drain holes, adjoining clips and seals for secure installation.

Power Generation
Oil & Gas
View Details
FSS-AG panel filter for gas turbine and industrial air intake

P2C-1-AG

Airguard Envirocare P2C-1-AG is a permanent, cleanable OEM-equivalent coalescer panel filter engineered for Altair® System 2 and Altair® Neptune air intake systems. Built with robust stainless-steel mesh construction, it provides a durable replacement solution for demanding offshore, coastal and industrial applications.

Power Generation
Oil & Gas
View Details
V99XS-GT2 coalescer panel filter for gas turbine air intake

V99XS–GT–AG

Airguard Envirocare V99XS-GT-AG is an OEM-equivalent coalescer panel filter designed for demanding gas turbine, marine, offshore wind and industrial air intake applications. It provides a reliable replacement solution for compatible Altair® and other OEM air intake systems.

Oil & Gas
Marine
View Details