Introduction

Four names come up again and again in gas turbine intake filtration: Altair System 2, Altair Neptune, Altair Vega and Altair Aquila. They are the Parker Altair systems that protect turbines on power stations, offshore platforms, marine vessels and industrial sites — and when a filter in one of them needs replacing, the plant does not need a lecture on filtration theory. It needs to know which filter fits which system, and how to order the equivalent without a shutdown. This guide answers exactly that, system by system. Airguard Envirocare manufactures OEM-quality equivalents for all four — the Altair System 2 range included — cross-referenced to 153 Altair part numbers across 23 products, made in Wolverhampton, UK, under ISO 9001.

Why One Guide for Four Systems

The four systems are related but distinct, and that is precisely why they get confused. A filter listed for "Altair" in general may be right for System 2 and wrong for Aquila, or right for the pre-filter stage and wrong for the final stage. The most common mistake in Altair replacement procurement is treating the four names as interchangeable — and the second most common is ordering by size alone, without checking the stage. This guide keeps the two questions separate: which system, and which stage inside it.

Altair System 2

Altair System 2 is a high-velocity gas turbine intake filtration platform built for demanding environments, including offshore and coastal installations. Parker's documentation identifies a cleanable PBR pre-filter and three disposable high-efficiency bag-filter options within the System 2 range, with different efficiency and pressure-loss characteristics between options such as HVL, HVX and HVY. The system is designed around high airflow, dust-holding capacity, salt removal and pressure-loss considerations — which is why the replacement must be matched stage by stage, not by size alone.

Airguard's equivalents for System 2 cover the full staged train. The CP2-AG is an OEM-equivalent coalescer panel filter engineered for Altair System 2, Neptune and Vega air intake systems, removing moisture, salt mist and liquid aerosols from intake air for offshore, marine and power generation applications. The PBR-AG is an OEM-equivalent pre-pocket filter for the same systems, built for high-velocity mechanical pre-filtration in offshore and coastal use. The HV2-AG is an Altair-equivalent high-efficiency pocket filter for the final stage. The same System 2, Neptune and Vega compatibility is listed for the PFA-AG and PFAH-AG pre-pocket filters, the PB1-AG and PBRH-AG pre-pocket filters, the HXA-AG and HVX-AG high-efficiency pocket filters, the PC2-AG coalescer panel filter and the FDSB8-AG pre-filter panel — so the whole intake train for a System 2 installation can be specified from one equivalent range, matched on the part number already in use.

Altair Neptune

Altair Neptune installations need the same staged attention, particularly where the intake operates in coastal, marine or contaminated environments. Neptune shares the System 2 family of Airguard equivalents: the CP2-AG coalescer, the PBR-AG, PFA-AG, PFAH-AG, PB1-AG and PBRH-AG pre-pocket filters, the HV2-AG, HXA-AG and HVX-AG high-efficiency pocket filters, the PC2-AG coalescer and the FDSB8-AG pre-filter panel are all listed as compatible with Altair System 2, Neptune and Vega together.

That shared compatibility is useful — but it does not eliminate the need to select the correct filtration stage. A Neptune pre-filter and a Neptune final filter are different products with different jobs, even when both carry the same system name. Confirm the stage first: pre-filter, coalescer or high-efficiency final. Then confirm the part number. The engineering team can assess the existing Neptune specification and produce a direct equivalent matched on dimensions, media and performance, including bespoke sizes where the installed housing is non-standard.

Altair Vega

Altair Vega configurations vary according to the required intake protection. Parker documentation describes Vega arrangements involving vane separation and filter coalescing, including configurations designed to handle airborne water, sea spray and fine droplets, for gas turbine, diesel-engine and HVAC applications. The filter cannot be evaluated independently of the air-intake architecture — a Vega filter is part of a system that is managing water as well as dust.

The practical consequence is that a Vega replacement must be checked against the intake's water-handling stage as well as its particulate stage. The coalescer stage matters most here: the CP2-AG and PC2-AG coalescer panel filters are listed for Vega alongside System 2 and Neptune, and they drain moisture and liquid aerosol away before it reaches the final filter. Behind them, the same pre-pocket and high-efficiency pocket equivalents — PBR-AG, PFA-AG, HV2-AG and the rest of the family — complete the train. As with the other systems, the part number is the fastest route to the right match, and the quote comes back within 24 hours.

Altair Aquila

Altair Aquila should be treated as a separate system reference during specification rather than assuming that every System 2, Neptune or Vega filter is automatically interchangeable. Airguard identifies its Altair-compatible range as covering System 2, Vega, Neptune and Aquila — but the engineering process remains the same for each: identify the installed configuration, establish the filter specification, verify physical compatibility, confirm performance requirements and review environmental conditions.

For Aquila, the match is made by part number and dimensions. Send the Aquila part number — or the filter's dimensions and the system name — and the engineering team assesses the existing specification and produces a direct equivalent matched on dimensions, media and performance. Do not order an Aquila replacement on the basis that a System 2 filter "looks the same": the frame, depth, gasket and pocket configuration are part of the specification, and a filter a few millimetres out will not seal. An unsealed filter is a bypass path, and a bypass path is unfiltered air reaching the compressor.

Side by Side: The Four Systems

Altair system

Typical setting

Airguard equivalents

System 2

High-velocity intake, offshore and coastal

CP2-AG, PBR-AG, PFA-AG, HV2-AG and more — matched by part number

Neptune

Coastal, marine, contaminated intake air

Same System 2 family — CP2-AG, PBR-AG, HV2-AG and more

Vega

Water and spray handling, gas turbine, diesel, HVAC

CP2-AG and PC2-AG coalescers, plus pre-pocket and HE pocket family

Aquila

Named system, separate specification

Matched by part number and dimensions — send system name and part number

The table is a starting point, not a specification. Every row ends the same way: the part number decides the match, and the stage decides the product.

How to Match Your Part Number

The fastest route to the right equivalent is the part number. Airguard's OEM Part Number Guide and the Altair hub page list every cross-reference: find your Altair part number and it shows the matching Airguard filter. The hub covers 153 part numbers across 23 Airguard products. If your part number is not listed, send it to the engineering team with the dimensions and the system name. The team assesses the existing specification and produces a direct equivalent matched on dimensions, media and performance — including bespoke sizes where the installed housing is non-standard. Quote requests are answered within 24 hours, and the standard lead time for made-to-order industrial filters is four weeks.

Staging Still Decides the Filter

A major mistake in replacement procurement is treating every filter in the intake system as performing the same job. A staged filtration system uses different elements to manage different contaminant types, and the gas turbine intake filters guide sets out the full train. In an Altair system the stages are:

  • Pre-filter: removes larger contaminants and reduces the loading on downstream filtration. The PBR-AG is specified as an OEM-equivalent pre-pocket filter for Altair System 2, Neptune and Vega applications, with high-velocity mechanical pre-filtration for offshore and coastal use.

  • Coalescer: manages moisture and liquid aerosol, draining them away before they reach the final stage. The CP2-AG combines coalescing and mechanical filtration for offshore, marine and land-based installations.

  • High-efficiency final: captures fine particulate. The high efficiency pocket filter for Altair System 2 is covered in its own guide — the final stage deserves its own specification check, because its efficiency class decides what reaches the compressor.

A pre-filter, a coalescer and a high-efficiency pocket filter perform different functions. Ordering the wrong stage — even from the right system family — leaves the turbine unprotected in exactly the place the original design was protecting it.

Verifying the Replacement Before It Goes In

Before an Altair equivalent goes into the intake, verify it the same way you would verify any OEM-equivalent replacement:

  • Dimensions: face size, depth, pocket depth, frame, gasket location and holding-frame interface.

  • Efficiency: the rated class and the test method behind it. A class without test documentation is an assertion, not a specification.

  • Pressure drop: the pressure-loss curve across the operating airflow range, not a single number. Different System 2 configurations have different pressure-loss and efficiency characteristics, so the curve is part of the match.

  • Media and construction: media type, frame material, support construction, gasket material and seal configuration — and for the coalescer stage, how the media handles water.

  • Environment: coastal, offshore, dusty or humid. An equivalent for a land-based installation may not be the right choice for a marine one.

For EPC projects, these parameters belong in the technical submittal rather than relying solely on an "Altair equivalent" description. The full EPC checklist is in the Altair equivalent filters buyer's guide, and the general principles are set out in the Altair equivalent gas turbine intake filters guide.

Why Plants Switch to Parker / Altair Equivalent Filters

The installed base of Altair systems is large, the original systems are well documented, and the equivalent range is mature — which is why Parker / Altair equivalent Filters are the most-specified OEM-equivalent replacement in gas turbine intakes. Plants switch for three practical reasons: availability (a UK manufacturer answering quotes in 24 hours and delivering made-to-order filters on a four-week lead time, instead of a single-source queue), consistency (the same equivalent, reproduced to the same specification, across the project lifecycle), and engineering support (a team that assesses the existing specification rather than selling a size). The saving is real only if the equivalent performs — which is why every claim in this guide comes back to verification: part number, dimensions, class, media and pressure drop, in writing, before the order.

Wrapping Up

Altair System 2, Neptune, Vega and Aquila are four systems, not four names for one filter. System 2 is the high-velocity offshore platform; Neptune is the coastal and marine workhorse; Vega is the water-handling configuration; Aquila is a separate system reference that is matched by part number. The equivalents for the first three share a family of Airguard products — CP2-AG, PBR-AG, PFA-AG, HV2-AG and the rest — while Aquila is matched on the part number and dimensions you send. In every case the route is the same: confirm the system, confirm the stage, find the part number, verify the specification. To start, send the Altair part number and the system name — and request a free estimate for the filters the intake needs.

FAQs

What filter fits Altair System 2?

An Altair System 2 filter depends on the stage: the CP2-AG coalescer panel filter for moisture and liquid aerosol, the PBR-AG or PFA-AG pre-pocket filter for the first stage, and the HV2-AG, HXA-AG or HVX-AG high-efficiency pocket filter for the final stage. Match by your Altair part number on the Altair equivalent filters hub — 153 part numbers across 23 Airguard products are cross-referenced there.

What is an Altair Neptune filter?

An Altair Neptune filter is a replacement element for a Parker Altair Neptune intake system, typically operating in coastal, marine or contaminated environments. Airguard equivalents for Neptune share the System 2 family — CP2-AG coalescer, PBR-AG and PFA-AG pre-pocket filters, and HV2-AG high-efficiency pocket filters — matched by part number and stage.

What is an Altair Vega filter?

An Altair Vega filter is a replacement element for a Parker Altair Vega intake system, where the intake architecture manages airborne water, sea spray and fine droplets through vane separation and coalescing, for gas turbine, diesel-engine and HVAC applications. The coalescer stage — CP2-AG or PC2-AG — matters most, backed by the pre-pocket and high-efficiency pocket equivalents.

What is an Altair Aquila filter?

An Altair Aquila filter is a replacement element for a Parker Altair Aquila intake system. Aquila is a separate system reference — do not assume a System 2, Neptune or Vega filter is automatically interchangeable. Airguard matches Aquila equivalents by part number and dimensions: send the Aquila part number and the system name and the engineering team will identify the match.

Are Altair System 2, Neptune, Vega and Aquila filters interchangeable?

No. They are related but distinct systems, and a filter for one is not automatically right for another. Always confirm the system and the filtration stage — pre-filter, coalescer or high-efficiency final — before ordering, and verify dimensions, efficiency class, media and pressure drop for the specific replacement.

References