Airguard Envirocare FAL-AG i an OEM-equivalent indu trial panel filter compatible with Altair Sy tem 2, Altair Neptune and Altair Vega.

Brand
Airguard Envirocare
Flow Rate
0.25 – 0.79 m³/s (900 – 2,840 m³/h) at 1.5 – 2.5 m/s
Division
Filtration
Efficiency
Available on request
Industry
Oil & Gas, Power Gen, Wind, HVAC
Temperature
Up to 80
Application
Offshore, Land-based
Height
407 / 500 / 598 mm
Technology
Filtration
Width
407 / 500 / 598 mm
Product Type
Filter Panel
Depth
22 / 50 mm
Product Style
Coalescer Panel
OD
n/a
Media
Crimped Knitted Monofilament Aluminium Mesh, between expanded aluminium support mesh
ID
n/a
Construction
Aluminium
Weight
2.5 KG or 5 lb
Classification
Available on request
Bespoke
Available
Product
FAL-AG
Altair Systems
Altair Part Numbers
Gas Turbine Manufacturers
Industrial Sector
The Airguard Envirocare FAL-AG Industrial panel uses crimped, knitted aluminium mesh between expanded aluminium support mesh, housed in a lightweight aluminium frame. It is available as an Altair® / Parker® system filter replacement, matching the original dimensions, media specification and mounting method for existing housings, along with a 12-month manufacturer's warranty.
Non-standard sizes are available, with 22 mm and 50 mm depths, adjoining clips, seals and drain holes for easy moisture drainage. The knitted aluminium mesh coalesces water droplets and salt aerosols, helping stop moisture from reaching the turbine or downstream filter. It is also fibre-shed resistant and non-flammable, making it suitable for demanding gas turbine and diesel engine intake environments.
Share part number/spec, dimensions, airflow and efficiency, and our team will respond within 24 hours.
From purchase order to delivery on site. Every FAL-AG is built, checked and shipped by our own team.
Common questions about FAL-AG.
Clean the FAL-AG once pressure loss reaches 200 Pascals, rather than on a fixed schedule. Sites with heavy salt or moisture loading will reach this threshold faster than drier inland sites.
The FAL-AG is a direct replacement for Altair System 2, Altair Neptune and Altair Vega panels, cross-referencing to Parker Hannifin / Altair part number SMC/006496F and related references SMC/006507F, SMC/006593F, P2C-1-002, P2C-1-003 and P2C-1-004. It is used across GE, Rolls-Royce, Siemens and Solar Turbines gas turbine intake systems.
Aluminium construction gives a notably lighter panel than a stainless steel equivalent, which is helpful where filters are handled and cleaned frequently by hand. For the harshest coastal or offshore salt exposure, the stainless steel FSS-AG may be the better choice; our team can advise based on your site conditions.
Yes, greasy contaminants can be removed by washing with a non-ionic cleaning detergent and rinsing with fresh water, restoring the filter to near its original efficiency and pressure loss.
The FAL-AG industrial panel filter is an OEM-equivalent filtration solution listed as compatible with Altair System 2, Altair Neptune, and Altair Vega. It is intended for industrial air intake applications where an existing filter needs to be matched by specification.
Yes. The FAL-AG is listed by Airguard Envirocare as an OEM-equivalent industrial panel filter compatible with Altair System 2, as well as Altair Neptune and Altair Vega systems.
The FAL-AG is listed as compatible with Altair Neptune and Altair Vega systems. For accurate replacement matching, provide the existing OEM part number, dimensions, frame depth and airflow specification.
The currently available product source confirms compatibility with Altair System 2, Neptune, and Vega, but does not expose a specific Parker Hannifin part number that should be quoted as a verified FAL-AG cross-reference. If you have a Parker or Altair part number, Airguard Envirocare can assess it for specification matching rather than relying on an unverified cross-reference.
Yes. Airguard Envirocare offers custom sizing and specification matching. A technical drawing, sample, dimensions or existing part number can be used to assess the appropriate replacement.
Choose the FAL-AG when its Altair System 2, Neptune or Vega compatibility and filter specification match your existing installation. For applications with different OEM systems or filtration requirements, Airguard can compare the existing specification against related industrial panel and coalescer filter families.
FAL-AG should be selected according to the environmental conditions stated in its product specification, including factors such as dust, moisture, salt, humidity, temperature and airborne contamination where applicable. The installed system and required filtration performance should be checked before selection.
Where FAL-AG is identified as Altair-compatible, Airguard Envirocare positions it as an OEM-equivalent or specification-matched replacement. Exact compatibility should be confirmed against the installed filter's part number, dimensions and required performance. The available product information identifies compatibility with Altair System 2, Altair Neptune and Altair Vega.
Yes. Airguard Envirocare can provide available technical information for FAL-AG, including technical datasheets, technical drawings, and other relevant information on request.
The FAL-AG manufacturing origin is the United Kingdom.
Depending on the product, order requirements, and delivery location, FAL-AG can be delivered in approximately 2 to 7 working weeks.
Use of an alternative filter should not be described as automatically voiding a gas turbine warranty. Warranty terms are set by the turbine OEM and the applicable contract, so customers should confirm the requirements with the OEM or operator before installation. Where this product is used as an OEM-equivalent replacement, its dimensions and performance specifications should be verified for the specific installation.
Yes. Airguard Envirocare offers a 12-month manufacturer's warranty for FAL-AG.