Airguard Envirocare
Altair Part Number K26462

CP2–AGCoalescer Panel Filters

Cross-references to Altair part number K26462 also used in V99XS–GT–AG, V99X–GT2–AG

Airguard Envirocare CP2-AG i an OEM-equivalent coale cer panel filter engineered for Altair Sy tem 2, Altair Neptune and Altair Vega air intake y tem .

Coalescer Panel Filter
Request a quoteFact sheet
V99X-GT2-AG coalescer panel filter for gas turbine air intake

Brand

Airguard Envirocare

Flow Rate

9 m/s (1771 FPM)

Division

Filtration

Efficiency

G4

Industry

Oil & Gas, Power Gen, Marine, Wind, HVAC

Temperature

upto 80 °C

Application

Offshore, Marine, Land-based

Height

Standard and non-standard

Technology

Coalescing and Mechanical Filtration

Width

Standard and non-standard

Product Type

Filter Panel

Depth

22 / 50 mm

Product Style

V-Pleated Coalescer Panel, Cleanable

OD

n/a

Media

Polyester Mat, 100% Silicone-Free, between Plastic-Coated Wire Mesh

ID

n/a

Construction

Stainless Steel Frame; Plastic-Coated Wire Mesh

Weight

2.5 KG or 5 lb

Classification

G4 / EU4 (EN 779:2002); 87% initial, 93% average arrestance; 99% at 5 µm

Bespoke

Available

Request Pricing

Share part number/spec, dimensions, airflow and efficiency, and our team will respond within 24 hours.

We use the details you provide only to respond to your enquiry, as set out in our Privacy Policy. To ask about, correct or delete your data, see Your Data Rights.

Customer reviews4.6Based on 9 reviews
55
44
30
20
10
What customers mention
Good communication on lead timesTop quality and great supportStraightforward specificationExactly to spec, fast turnaroundLow pressure drop, high dust holdingEffective and well made

How ordering works

From purchase order to delivery on site. Every CP2–AG is built, checked and shipped by our own team.

01
Purchase Order
Confirm your quote and raise a PO. We acknowledge it and confirm lead time in writing.
02
Production
Your CP2–AG is made to order in our Wolverhampton factory, to your sizes.
03
Quality Assurance
Every filter is inspected under our ISO 9001:2015 quality management system.
04
Packing
Custom packaging and labelling, with test certification and documentation.
05
Shipping
Despatched worldwide with tracking, so purchasing and site teams stay informed.

Frequently Asked Questions

Common questions about CP2–AG.

The CP2-AG removes moisture, salt mist and liquid aerosols from gas turbine intake air. It is designed for offshore, marine, and power generation applications.

Yes. The CP2-AG is an OEM-equivalent replacement for Altair System 2, Altair Neptune and Altair Vega air intake systems, with standard and custom sizes available.

The CP2-AG is designed for demanding environments such as offshore oil and gas, marine propulsion and offshore wind applications, where moisture and salt aerosols can affect turbine components.

The CP2-AG is an OEM-equivalent coalescer panel filter compatible with Altair System 2, Altair Neptune, Altair Vega, and other equivalent OEM air intake systems.

Yes. Airguard Envirocare lists the CP2-AG as an OEM-equivalent replacement for compatible Altair System 2, Neptune and Vega air intake systems.

The CP2-AG belongs to Airguard Envirocare's coalescer panel range used across demanding industrial sectors, including power generation, marine, oil & gas and industrial air intake applications. The final application should be matched to the exact system requirements.

Yes. Submit the existing OEM or manufacturer part number, along with dimensions, airflow, frame depth and filtration requirements. This information can be used to assess whether the CP2-AG is the correct OEM-equivalent replacement.

The available product information confirms compatibility with Altair System 2, Neptune and Vega, but does not expose specific CP2-AG Parker or Altair part numbers. Specific cross-reference numbers should only be added after verification from the product specification.

The right coalescer panel depends on the installed OEM system, application, airflow, environmental conditions, required performance and physical dimensions. PB1P8-AG is specifically listed for Altair System 2, Neptune and Vega, while PC2-AG is listed for gas turbine, engine, HVAC and offshore wind applications.

The available product information identifies compatibility with Altair System 2, Altair Neptune and Altair Vega and other equivalent OEM air intake systems.

CP2-AG should be selected according to the environmental conditions stated in its product specification, including factors such as dust, moisture, salt, humidity, temperature and airborne contamination where applicable. The installed system and required filtration performance should be checked before selection.

Where CP2-AG is identified as Altair-compatible, Airguard Envirocare positions it as an OEM-equivalent or specification-matched replacement. Exact compatibility should be confirmed against the installed filter's part number, dimensions and required performance. The available product information identifies compatibility with Altair System 2, Altair Neptune and Altair Vega and other equivalent OEM air intake systems.

Yes. Airguard Envirocare can provide available technical information for CP2-AG, including technical datasheets, technical drawings and other relevant information on request.

The CP2-AG manufacturing origin is the United Kingdom.

Depending on the product, order requirements and delivery location, CP2-AG can be delivered in approximately 2 to 7 working weeks.

Use of an alternative filter should not be described as automatically voiding a gas turbine warranty. Warranty terms are set by the turbine OEM and the applicable contract, so customers should confirm the requirements with the OEM or operator before installation. Where this product is used as an OEM-equivalent replacement, its dimensions and performance specifications should be verified for the specific installation.

Yes. Airguard Envirocare offers a 12-month manufacturer's warranty for CP2-AG.

Can’t find it? Ask our team