Airguard Envirocare
Altair Part Number PC1/PAM00005-129

PC1–AG

Coalescer Panel Filters

Cross-references to Altair part number PC1/PAM00005-129

Airguard Envirocare PC1-AG i an OEM-equivalent coale cer panel filter engineered for ga turbine ventilation, die el and ga engine intake, HVAC.

Coalescer Panel Filter
Request a quoteFact sheet
PC1-AG coalescer panel filter for gas turbine air intake
Technical specifications

Brand

Airguard Envirocare

Flow Rate

Up to 9 m/s face velocity (1,771 FPM)

Division

Filtration

Efficiency

G3

Industry

Oil & Gas, Power Gen, Marine, Wind, HVAC

Temperature

n/a

Application

Offshore, Marine, Land-based

Height

Standard and non-standard, to holding frame

Technology

Coalescing and Mechanical Filtration (3-stage vane/coalescer/vane)

Width

Standard and non-standard, to holding frame

Product Type

Filter Panel

Depth

n/a

Product Style

Corrugated Coalescer Panel, Cleanable

OD

n/a

Media

Synthetic Media Core, between Stainless Steel Wire Mesh

ID

n/a

Construction

Stainless Steel 304L / 316L channel frame and mesh

Weight

2.5 KG or 5 lb

Classification

G3 (EN 779:2002); 80% gravimetric arrestance

Bespoke

Available

Request Pricing

Share part number/spec, dimensions, airflow and efficiency, and our team will respond within 24 hours.

We use the details you provide only to respond to your enquiry, as set out in our Privacy Policy. To ask about, correct or delete your data, see Your Data Rights.

Customer reviews4.6Based on 9 reviews
55
44
30
20
10
What customers mention
Straightforward specificationGood communication on lead timesTop quality and great supportConsistent between batchesExactly to spec, fast turnaroundLow pressure drop, high dust holding

How ordering works

From purchase order to delivery on site. Every PC1–AG is built, checked and shipped by our own team.

01
Purchase Order
Confirm your quote and raise a PO. We acknowledge it and confirm lead time in writing.
02
Production
Your PC1–AG is made to order in our Wolverhampton factory, to your sizes.
03
Quality Assurance
Every filter is inspected under our ISO 9001:2015 quality management system.
04
Packing
Custom packaging and labelling, with test certification and documentation.
05
Shipping
Despatched worldwide with tracking, so purchasing and site teams stay informed.

Frequently Asked Questions

Common questions about PC1–AG.

The PC1-AG is suitable for onshore, coastal, offshore and marine environments, with 316L stainless steel recommended for sites with continuous salt exposure.

The PC1-AG helps remove moisture, salt mist and fine liquid aerosols from incoming air, helping protect gas turbines, engines and other intake equipment.

The PC1-AG is available with 304L or 316L stainless-steel frames in standard or custom sizes, with sealing gaskets and integral clips supplied for installation.

The PC1-AG is an OEM-equivalent coalescer panel filter designed for gas turbine ventilation, diesel and gas engine intake, industrial HVAC and offshore wind turbine air intake systems.

Yes. Airguard Envirocare lists the PC1-AG for diesel and gas engine air intake applications, where the filter can be matched to the required airflow and existing installation.

Yes. The PC1-AG is listed for offshore wind turbine air intake systems, alongside gas turbine and industrial HVAC applications.

The currently available product source confirms the PC1-AG's application range but does not expose a verified Parker Hannifin or Altair® part number that should be published as a direct cross-reference. Existing OEM part numbers can be submitted for specification matching.

Provide the current filter part number, dimensions, depth, airflow, efficiency, and application details. A drawing or photograph of the existing filter can also help confirm the correct replacement configuration.

The PC1-AG and PB1P8-AG are both coalescer panel filters, but the PB1P8-AG is specifically listed as compatible with Altair System 2, Neptune, and Vega. The correct choice depends on your installed system and filter specification.

PC1-AG should be selected according to the environmental conditions stated in its product specification, including factors such as dust, moisture, salt, humidity, temperature, and airborne contamination where applicable. The installed system and required filtration performance should be checked before selection.

Where PC1-AG is identified as Altair-compatible, Airguard Envirocare positions it as an OEM-equivalent or specification-matched replacement. Exact compatibility should be confirmed against the installed filter's part number, dimensions and required performance. The available product information lists gas turbine, diesel and gas engine, HVAC and offshore wind applications.

Yes. Airguard Envirocare can provide available technical information for PC1-AG, including technical datasheets, technical drawings and other relevant information on request.

The PC1-AG manufacturing origin is the United Kingdom.

Depending on the product, order requirements and delivery location, PC1-AG can be delivered in approximately 2 to 7 working weeks.

Use of an alternative filter should not be described as automatically voiding a gas turbine warranty. Warranty terms are set by the turbine OEM and the applicable contract, so customers should confirm the requirements with the OEM or operator before installation. Where this product is used as an OEM-equivalent replacement, its dimensions and performance specifications should be verified for the specific installation.

Yes. Airguard Envirocare offers a 12-month manufacturer's warranty for PC1-AG.

Can’t find it? Ask our team